Các lỗi thường gặp

Code :
  • Code: E02
  • Description: Elevator Motor Lock
    • When the light path of the Upper limit sensor or the Lower limit sensor is not cut within 10 seconds after the Elevator motor is activated. • If the light path of both the Upper limit and Lower limit sensors are blocked when the Elevator motor is activated. • If excessive current is detected 0.3 seconds consecutively after the Elevator motor is activated.
  • Code: E03
  • Description: Clamp Motor Lock [During Clamp Motor Initial Positioning]
    • If the light path of the Clamp senors both A and B are not opened within 13 seconds after after the Clamp motor is activated. [During Master Release from the Clamp Plate] • If the light path of the Clamp sensor B is not blocked within 3 seconds after the Clamp motor is activated. • If the light path of the Clamp sensor B is not opened within 12 seconds after the Clamp motor is activated. [When the Clamp Plate opens during Master Clamping] • If the light path of the Clamp sensor B is not blocked within 3 seconds after the Clamp motor is activated. • If the light path of the Clamp sensor A is not opened within 5 seconds after the Clamp motor is activated. [When the Clamp Plate closes during Master Clamping] • If the light path of the Clamp sensor B is not opened within 5 seconds after the Clamp motor is activated.
  • Code: E04
  • Description: Ink Overflow
    • If the Overflow sensor detects excessive ink in the Squeegee unit.
  • Code: E05
  • Description: Print Positioning Motor Lock
    • If the Vertical centering sensor status has not been changed from ON to OFF (or OFF to ON) within 3550 ms after the Print positioning motor activated.
  • Code: E06
  • Description: Position-A Sensor Malfunction
    • If Position-A sensor cannot be detected (or keeps detecting) even though the Main motor encoder sensor signal is making the output after the Main motor is activated.
  • Code: E07
  • Description: Master Compressing Motor Lock
    [When compressing] • If the light path of the Master compressing sensor is not opened within 10 seconds after the Master compressing motor is activated. [When returning back] • If the light path of the Master compressing sensor is not opened (or closed) within 1 second after the Master compressing motor is activated.
  • Code: E08
  • Description: Communication Error between TR and Interface Accessaries
    • If a communication error has occurred between the CPU and the interface accessaries.
  • Code: E10
  • Description: Shading Error
    • If the Shading compensation is not made.