Code: E1

Description: Main Motor Lock
• If excessive current is detected 0.3 seconds consecutively after the Main motor is activated.
• If no Encoder sensor output after Main motor is activated.

Code: E12

Description: Master removal motor lock
• Excessive current to the motor is detected three time consecutively during the current check made every 100 ms.

Code: E13

Description: Cutter motor Lock
• If the Cutter home position switch is not turned OFF within 500 ms after the Cutter motor is activated.
• If the Cutter end position switch is not pressed within 2000 ms after the Cutter motor is activated.

Code: E16

Description: Inking Motor Lock
• If excessive current is detected 2.5 seconds consecutively after the Inking motor is activated.

Code: E19

Description: TPH pressure error [During TPH Up Positioning]
• If the light path of the TPH pressure sensor is not opened within 10 seconds after the Write pulse motor is activated. [During TPH Down Positioning]
• If the light path of the TPH pressure sensor is not blocked within 10 seconds after the Write pulse motor is activated.

Code: E3

Description: Clamp Motor Lock [During Clamp Motor Initial Positioning]
• If the light path of the Clamp senors both C and L are not opened within 10 seconds after after the Clamp motor is activated. [During Master Release from the Clamp Plate]
• If the light path of the Clamp sensor L is not blocked within 10 seconds after the Clamp motor is activated.
• If the light path of the Clamp sensor C is not opened within 10 seconds after the Clamp motor is activated. [When the Clamp Plate opens during Master Clamping]
• If the light path of the Clamp sensor L is not blocked within 10 seconds after the Clamp motor is activated.
• If the light path of the Clamp sensor C is not opened within 10 seconds after the Clamp motor is activated. [When the Clamp Plate closes during Master Clamping]
• If the light path of the Clamp sensor L is not opened within 10 seconds after the Clamp motor is activated.

Code: E4

Description: Ink Overflow
• If the Overflow sensor detects excessive ink in the Squeegee unit.

Code: E6

Description: Position-A Sensor Malfunction
• If Position-A sensor cannot be detected (or keeps detecting) even though the Main motor encoder sensor signal is making the output after the Main motor is activated.