Các lỗi thường gặp

Code :
  • Code: P15-4
  • Description: Communication error with AF-CPU.
  • Code: P17-20
  • Description: Solenoid counter is not connected.
  • Code: P18-531
  • Description: Print drum lock sensor is still ON even after 100 milliseconds after the print drum lock solenoid is activated.
  • Code: P19-207
  • Description: TPH pressure sensor does not go OFF within 2 seconds after the thermal-pressure motor activates in the decompressing direction, orduring home positioning operation.
  • Code: P19-208
  • Description: TPH pressure sensor does not go ON within 2 seconds after the thermal-pressure motor activates in the decompressing direction.
  • Code: P19-216
  • Description: TPH pressure sensor does not go OFF within 500 millisecond after the thermal-pressure motor activates in the compressing direction.
  • Code: P19-217
  • Description: TPH pressure sensor does not go ON within 2 seconds after the thermal-pressure motor activates in the compressing direction.
  • Code: P20-415
  • Description: Paper-ejection-wing home sensor does not go OFF within 7,000 milliseconds after the paper ejection wing motor activates in thecounterclockwise direction from the home position.