Code: P03-508

Description: Clamp sensor A is ON after the A-position compensating movement is completed.

Code: P03-545

Description: Clamp unit is not in the home position while the print drum is in movement (cause due to the clamp motor).

Code: P04-513

Description: The overflow sensor was ON for a set number of times in succession during the 10-millisecond-interval overflow-sensor check.

Code: P05-603

Description: The vertical-centering sensor does not switch ON even when the vertical-positioning pulse motor activated in the image-down direction for5 seconds during vertical home positioning movement.

Code: P05-604

Description: The vertical-centering sensor does not switch OFF even when the vertical-positioning pulse motor activated in the image-up direction for 5seconds during vertical home positioning movement.

Code: P05-605

Description: Even though the vertical positioning motor stopped according to the vertical centering sensor detection, the stopping position does notcorrespond with the programmed position. (GA control error).

Code: P05-612

Description: The one-step-positioning key was pressed with vertical-print-position information undefined.

Code: P08-951

Description: Print job executed was not in correct RisoRinc format.