Code: 0102

Description: Even though the machine carries out the regular movement, the output of Limit Sensor does not reach the expected value.
Causes: Limit Sensor does not work correctly or is broken.

Code: 0107

Description: Linear Encoder Setup has not been done.
Causes: Linear Encoder Setup has not been done. Linear Encoder Setup is ended before it is completed.

Code: 0109

Description: Even though the machine carries out the regular movement, the output of the Wiper Sensor does not reach the expected value.
Causes: Wiper Motor error Defect of Wiper Unit Defect of Wiper Sensor Cut-line or short-circuit of cable and Flexible cable

Code: 0110

Description: Input value from Linear Encoder is not changed by the Linear Encoder origin setup. When Motor stops during printing, expected movement is not completed on some head.
Causes: Read error of Linear Encoder. Read error of Encoder on Scan Motor side. Belt is not fixed to Head Carriage firmly.

Code: 0112

Description: Communication error with Cartridge IC driver
Causes: Cartridge IC driver is broken. Cartridge IC driver cable has short circuited or cut-line.

Code: 0114

Description: This error occurs when the machine performs Flushing Position Detection
Causes: Flushing position in the Service menu has not been performed

Code: 0130

Description: There is a problem with Thermistor for Print Heater
Causes: Thermistor cable has short circuited or cutline. Thermistor has a problem.

Code: 0135

Description: Print Heater temperature has reached 60°C and above
Causes: Print Heater cable connection has a problem. Thermostat has a problem. Thermistor has a problem.