Các lỗi thường gặp

Code :
  • Code: S2-4110
  • Display: Door open Close it
  • Description: Ther front door is not securely latched.
  • Remedy: 1. Close the door until it locks into place. 2. Check if the cover open switch is work properly. If it is defective, replace it. 3. If the problem persists, replace the main PBA.
  • Code: U1-1211
  • Display: Error #U1-1211 Turn off then on
  • Description: Low heat error has occurred.
  • Remedy: Refer to the fuser error troubleshooting.
  • Code: U1-2112
  • Display: Error #U1-2112 Turn off then on
  • Description: Abnormal ADC has occurred. ZeroCross Signal detect error has occurred.
  • Remedy: Is the thermistor resistance value in 300-450Kohm? Yes : Replace the thermistor. No : Replace the fuser unit. If the problem persist after replacing the fusur unit, replace the SMPS board or Main board.
  • Code: U1-2121
  • Display: Error #U1-2121 Turn off then on
  • Description: Over heat error has occurred.
  • Remedy: Refer to the fuser error troubleshooting.
  • Code: U2-1112
  • Display: Error #U2-1112 Turn off then on
  • Description: LSU has some problem.
  • Remedy: Turn off the machine then on. If the problem persist, replace the LSU unit.
  • Code: U2-1114
  • Display: Error #U2-1114 Turn off then on
  • Description: LSU does not work but the Lready signal is detected.
  • Remedy: Turn off the machine then on. If the problem persist, replace the LSU unit.