Description: 1. All lamps on the operator panel blink.
Causes: DCU Mode : Perform DCU diagnostic code 05. If the DCU error code 95 is displayed, replace LSU.
Code: 10
Display: Not function of the gear of the fuser due to melting away
Description: The motor breaks away from its place due to gear melting away.
Causes: DCU Mode : Check if the Error States '60' '62' '68' occur. Check the operation of Fuser Erasing Lamp On/Off with the Error Code Check -10-.
Code: 11
Display: Paper Empty
Description: The paper lamp on the operator panel is on even when paper is loaded in the cassette.
Causes: 1. Bending or deformation of the actuator of the paper sensor. 2. The function of the engine board is defective Perform DCU mode: Perform DCU diagnostic code 8.
Code: 12
Display: Paper Empty without indication
Description: The paper lamp on the operator panel does not come on when the paper cassette is empty.
Causes: 1. Bending or deformation of the actuator of the paper sensor. 2. The function of the engine board is defective Perform. DCU mode : Perform DCU diagnostic code 8.
Code: 13
Display: Cover Open
Description: The ERROR lamp is on even when the print cover is closed.
Causes: 1. The Hook Lever in the top cover may be defective. 2. Check the connector (Engine Bfd-VPS) and circuit of the cover switch department in the Main Control board. Perform DCU mode : If Error state '64' occurs, Check the related codes of the Cover Open Error.
Code: 14
Display: No lamp on when the cover is open
Description: The ERROR lamp does not come on even when the printer cover is open
Causes: 1. Check the connector(CN8) and circuit of the cover switch department in the Main Control board. Perform DCU mode : If Error state '64' occurs, Check the related codes of the Cover Open Error
Code: 15
Display: Defective motor operation
Description: Main motor is not driving when printing, and paper does not feed into the printer, resulting 'Jam 0'.
Causes: 1. Motor harness or sub PCB may be defective. 2. Perform DCU diagnostic code 00 and Check the motor operation.
Code: 16
Display: No Power
Description: When system power is turned on, all lamps on the operator panel do not come on.
Causes: 1. Check if the power input and SMPS output are normal. 2. Check the inferiority of LED-Panel on the front-cover if the LED of Panel does not appear after normal warmingup.