Mã lỗi Sharp AL1566 — Trang 2/3
Code:
Tất cả lỗi (22)
10
10
11
11
13
16
16
81
84
E1-00
E1-82
E7-02
F5-02
H2-00
H3-00
H4-00
L1-00
L3-00
L4-01
L6-10
U2-04
U9-99
Code:
84
Description: IMC communication interface error (Framing)
A framing error occurs in communication between the CPU and the IMC.
Causes: IMC memory defect/data abnormality.
Description: IMC communication trouble
An abnormality occurs in communication between the CPU and the IMC.
Causes: IMC - CPU signal line abnormality IMC Memory defect/data abnormality
Description: IMC communication interface error (Overrun)
An overrun error occurs in communication between the CPU and the IMC.
Causes: IMC memory defect/data abnormality.
Description: LSU trouble
The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON)
Causes: LSU connector or LSU harness defect or disconnection Polygon motor rotation abnormality Laser beams are not generated. MCU PWB abnormality.
Description: Copy lamp lighting abnormality
The copy lamp does not turn on.
Causes: Copy lamp abnormality Copy lamp harness abnormality CCD PWB harness abnormality.
Description: Thermistor open
The thermistor is open. The fusing unit is not installed.
Causes: Thermistor abnormality Control PWB abnormality Fusing section connector disconnection The fusing unit is not installed.
Description: Heat roller high temperature detection
The fusing temperature exceeds 240°C.
Causes: Thermistor abnormality Control PWB abnormality Fusing section connector disconnection.
Description: Heat roller low temperature detection
The fusing temperature does not reach 185°C within 27 sec of turning on the power, or the fusing temperature keeps at 140°C.
Causes: Thermistor abnormality Heater lamp abnormality Thermostat abnormality Control PWB abnormality