Code :
- Code: F1-39
- Description: Punch dust sensor trouble
Punch dust sensor detection trouble
- Causes: Sensor breakage. harness breakage. Finisher control PWB trouble.
- Remedy: Use SIM3-2 to check the punch dust sensor operation
- Code: F1-40
- Description: Punch power trouble
Panch unit power discontinuity detection
- Causes: Punch control PWB defect
- Remedy: Replace the punch control PWB
- Code: F1-50
- Description: Finisher incompatibility error
Speed does not coincide between finisher and main unit
- Causes: AR-FN5N/F14 is connected to 31 sheet model
- Remedy: Connect AR-FN5A. Connect AR-F14N.
- Code: F1-53
- Description: Interface transport unit connection trouble
Interface transport unit connector disconnection
- Causes: Improper connection of connector between the finisher and the interface transport unit
- Remedy: Check the interface transport unit connector.
- Code: F1-81
- Description: Transport motor trouble
Transport motor trouble
- Causes: Motor lock. Motor rpm abnormality. Overcurrent to the motor. Finisher control PWB trouble.
- Remedy: Use SIM3-3-11 to check the front transport motor operation
- Code: F2-02
- Description: Toner supply failure
The value judged from the actual toner supply hysteresis differs greatly from the toner sensor value.
- Causes: Developing unit trouble Toner supply abnormality caused by installation of unpacked toner cartridge
- Remedy: Replace the developing unit. Use SIM 25-1 to perform DV stirring.
- Code: F2-04
- Description: Identification error
Identification error When the CRUM trademark differs. When the CRUM company code differs.
- Causes: CRUM chip failure Erroneous developing unit
- Remedy: Replace the CRUM chip. Replace the developing unit.
- Code: F2-58
- Description: Temperature humidity sensor abnormality
- Causes: Temperature humidity sensor connector disconnection. Short-circuit of the temperature humidity sensor was detected.
- Remedy: Check the connection of temperature humidity sensor. Replace the temperature humidity sensor.