Code: U2-80

Description: EEPROM read/write error (Scanner)
Scanner EEPROM write error
Causes: EEPROM abnormality Scanner PWB EEPROM access circuit abnormality
Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.

Code: U2-81

Description: Memory check sum error (Scanner)
Scanner memory check sum error
Causes: EEPROM trouble EEPROM which is not initialized is installed. Control circuit freeze by noises Scanner PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.

Code: U2-90

Description: EEPROM read/write error (PCU)
PCU EEPROM write error
Causes: EEPROM trouble PCU PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Record counter/adjustment values with the simulation to protect the data from being deleted. Use SIM16 to cancel U2 trouble. Replace the Controller PWB.

Code: U2-91

Description: Memory check sum error (PCU)
PCU memory check sum error
Causes: EEPROM trouble EEPROM which is not initialized is installed. EEPROM is not initialized. PCU PWB EEPROM access circuit trouble Hang of control circuit due to noises
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the simulation. Use SIM16 to cancel U2 trouble. Replace the Controller PWB.

Code: U6-00

Description: Desk/LCC communication trouble
Desk/LCC communication error Communication cable test error after turning on the power or exiting SIM.
Causes: Improper connection or disconnection of connector and harness Desk control PWB trouble Control PWB (PCU) trouble Noise or interference
Remedy: Canceled by turning OFF/ON the power. Check connection of the harness and connector in the communication line.

Code: U6-01

Description: Desk/LCC No. 1 tray lift-up trouble
Causes: Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor. Desk control PWB trouble Lift-up motor trouble
Remedy: Use SIM4-2 to check the upper limit sensor detection. Use SIM4-3 to check the lift-up motor operation.

Code: U6-02

Description: Desk No. 2 tray/LCC1 lift-up trouble
Causes: Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor. Desk control PWB trouble Lift-up motor trouble
Remedy: Use SIM4-2 to check the upper limit sensor detection. Use SIM4-3 to check the lift-up motor operation.

Code: U6-03

Description: Desk No. 3 tray/LCC2 lift-up trouble
Causes: Sensor trouble Tray trouble Defective connection or disconnection between the PWB and the motor. Desk control PWB trouble Lift-up motor trouble
Remedy: Use SIM4-2 to check the upper limit sensor detection. Use SIM4-3 to check the lift-up motor operation.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie