Code :
  • Code: E1-16
  • Description: IMC board compression image store memory error
    Access error of IMC standard compression memory
  • Causes: IMC board abnormality
  • Remedy: Replace the IMC PWB Remarks Standard compression image store memory abnormality
  • Code: E1-17
  • Description: IMC board smoothing IC error
    IMC smoothing IC abnormality
  • Causes: IMC board abnormality
  • Remedy: Replace the IMC PWB
  • Code: E1-80
  • Description: IMC PWB communication trouble (protocol)
    Communication trouble between MCU and IMC PWB (Protocol error)
  • Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1-81
  • Description: IMC PWB communication trouble (Parity)
    Communication trouble between MCU and printer IMC (Parity error)
  • Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1-82
  • Description: IMC PWB communication trouble (Overrun)
    Communication trouble between MCU and IMC PWB (Overrun error)
  • Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1-84
  • Description: IMC PWB communication trouble (Framing)
    Communication trouble between MCU and IMC PWB (Framing error)
  • Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1-88
  • Description: IMC PWB communication trouble (Timeout)
    Communication trouble between MCU and IMC PWB (Time-out error)
  • Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E7-02
  • Description: LSU trouble
    BD signal from LSU is not detected in a constant cycle. (Kept OFF or ON)
  • Causes: LSU connector or LSU inside harness trouble or disconnection Polygon motor rotation abnormality Laser does not illuminate. MCU PWB failure
  • Remedy: Check for disconnection of the LSU connector. Check the LSU operation with SIM 61-1. Check that the polygon motor rotates normally. Check laser LED lighting. Replace the LSU unit. Replace the MCU PWB.