Các lỗi thường gặp

Code :
  • Code: F1 04
  • Description: Finisher 1 elevator lower limit detection/ Finisher 2 stack tray lower limit detection. When the bin is shifted, the upper limit or the lower limit sensor is detected. / The elevator exceeds the lower limit.
  • Causes: Sensor defective Sorter/finisher control PWB abnormality
  • Remedy: Check sensor with SIM3-2.
  • Code: F1 05
  • Description: Finisher 1 elevator home / Finisher 2 stack tray sensor abnormality. The elevator does not detect the home position. / Stack tray sensors are turned on in the abnormal combination.
  • Causes: Sensor defective Sorter/finisher control PWB abnormality
  • Remedy: Check sensor with SIM3-2.
  • Code: F1 06
  • Description: Finisher shift motor abnormality. 1) Bin shift is not completed within 2.5 seconds after bin shift request
  • Causes: Motor lock Improper motor speed Overcurrent to motor Finisher control PWB defective
  • Remedy: Check bin shift motor operation with SIM3-4.
  • Code: F1 08
  • Description: Finisher staple shift motor trouble. Staple motor drive trouble
  • Causes: Motor lock Motor rpm abnormality Overcurrent to motor Finisher control PWB trouble
  • Remedy: Check the operation of the staple motor with SIM 3-3.
  • Code: F1 10
  • Description: Finisher staple unit operation trouble. Staple operation trouble
  • Causes: Motor lock Motor rpm abnormality Motor overcurrent Finisher control PWB trouble
  • Remedy: Check the staple motor operation with SIM 3-3.
  • Code: F1 11
  • Description: Finisher 1 pusher motor trouble / Finisher 2 boomerang rotation abnormality. Pusher motor trouble / Paddle solenoid abnormality
  • Causes: Motor lock / paddle solenoid operation abnormality / boomerang rotation sensor abnormality Motor rpm abnormality Motor overcurrent Finisher control PWB abnormality
  • Remedy: Check the finisher motor operation, the paddle solenoid operation with SIM 3-3 or check the boomerang rotation sensor with SIM 3-2.
  • Code: F1 14
  • Description: Finisher 2 stack tray abnormality. Stack tray control sensor abnormality
  • Causes: The paper surface sensor and the full stack sensor do not turn on even when a certain time is passed after starting the tray.
  • Remedy: Check the sensor operation with SIM 3-2.
  • Code: F1 15
  • Description: Finisher 1 elevator motor trouble / Finisher 2 stack tray motor lock. Elevator motor trouble
  • Causes: Motor lock Motor rpm abnormality Motor overcurrent Finisher control PWB trouble
  • Remedy: Check the elevator motor operation with SIM 3-3.