Description: Shading trouble (White correction) The CCD white scan level is abnormal when the shading.
Causes: Improper connection of the CCD unit flat cable Dirt on the mirror, the lens, and the reference white plate Copy lamp lighting abnormality CCD unit abnormality MCU PWB abnormality (When occurred in the SPF scan position.) Improper installation of the mirror unit
Remedy: Clean the mirror, lens, and the reference white plate. Check the light quantity and lighting status of the copy lamp (SIM 05-03). Check the MCU PWB.
Description: Improper cartridge (Destination error, life cycle error) The destination of the machine differs from that of the CRUM. The life cycle information is other than "Not used (FFh)."
Causes: CRUM chip defect Improper developing unit
Remedy: Replace the CRUM chip. Replace the developing unit.
Remedy: Use SIM 5-3 to check the copy lamp operations. When the copy lamp lights up. Check the harness and the connector between the CCD unit and the MCU PWB. When the copy lamp does not light up. Check the harness and the connector between the copy lamp unit and the MCU PWB. Replace the copy lamp unit. Replace the MCU PWB.