  • Code: E1 16
  • Description: IMC PWB standard compression memory error. Access error of standard compression memory on IMC PWB
  • Causes: IMC PWB abnormality
  • Remedy: Replace the IMC PWB Remarks Standard compression image store memory abnormality
  • Code: E1 17
  • Description: IMC PWB smoothing IC error. IMC PWB smoothing IC abnormality
  • Causes: IMC PWB abnormality
  • Remedy: Replace the IMC PWB
  • Code: E1 80
  • Description: IMC PWB communication trouble (protocol). Communication trouble between MCU and IMC PWB (Protocol error)
  • Causes: IMC PWB connector disconnection. Motherboard connector pin breakage. IMC PWB ROM defect, data failure.
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1 81
  • Description: IMC PWB communication trouble (Parity). Communication trouble between MCU and printer IMC (Parity error)
  • Causes: IMC PWB connector disconnection. Motherboard connector pin breakage. IMC PWB ROM defect, data failure.
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1 82
  • Description: IMC PWB communication trouble (Overrun). Communication trouble between MCU and IMC PWB (Overrun error)
  • Causes: IMC PWB connector disconnection. Motherboard connector pin breakage. IMC PWB ROM defect, data failure.
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1 84
  • Description: IMC PWB communication trouble (Framing). Communication trouble between MCU and IMC PWB (Framing error)
  • Causes: IMC PWB connector disconnection. Motherboard connector pin breakage. IMC PWB ROM defect, data failure.
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E1 88
  • Description: IMC PWB communication trouble (Time-out). Communication trouble between MCU and IMC PWB (Time-out error)
  • Causes: IMC PWB connector disconnection. Motherboard connector pin breakage. IMC PWB ROM defect, data failure.
  • Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
  • Code: E7 02
  • Description: LSU trouble. BD signal from LSU is not detected in a constant cycle (Kept OFF or ON)
  • Causes: LSU connector or LSU inside harness trouble or disconnection. Polygon motor rotation abnormality. Laser does not illuminate. MCU PWB failure.
  • Remedy: Check for disconnection of the LSU connector. Check the LSU operation with SIM 61-1. Check that the polygon motor rotates normally. Check laser LED lighting. Replace the LSU unit. Replace the MCU PWB.