Remedy: Is the paper size on the inserter tray consist with the size set at the copier control panel? Set the same paper size as that on the tray. Is the separation sensor working improperly? Replace the separation sensor. Perform the width adjustment of the inserter tray side guide.
Remedy: Is the condition improved when the copier power switch is turned OFF/ON? 1. Replace the copier LGC board. 2. Replace the IPC board. 3. Replace the inserter control board.
Description: Communication error between SYS board and LGC board
Remedy: (1) Check if the connectors J114 and J105 on the SYS board are disconnected. (2) Check if the connector J4 on the SLG board is disconnected. (3) Check if the harness connecting the SYS and SLG boards is open-circuited and the connector pins are disconnected. (4) Check if the harness connecting the SYS board and LGC board is open-circuited and the connector pins are disconnected. (5) Check the version of the FROM on the SYS board. (6) Check the version of the MROM on the LGC board. (7) Check the version of the SROM on the SLG board. (8) Replace the SYS board. (9) Replace the SLG board. (10) Replace the LGC board.
Remedy: (1) Initialize the HDD. (mode (08) - code "690" 2) (2) Check if the HDD is mounted. (3) Check if the specified HDD is mounted. (4) Check if the connector pins of the HDD are bent. (5) Check if the power supply connector is disconnected. (6) Check if the connector J107 on the SYS board is disconnected. (7) Replace the HDD. (8) Replace the SYS board. (9) Replace the harness.
Description: Communication error between SYS board and SLG board
Remedy: (1) Check if the connectors J114 and J105 on the SYS board are disconnected. (2) Check if the connector J4 on the SLG board is disconnected. (3) Check if the harness connecting the SYS and SLG boards is open-circuited and the connector pins are disconnected. (4) Check if the harness connecting the SYS board and LGC board is open-circuited and the connector pins are disconnected. (5) Check the version of the FROM on the SYS board. (6) Check the version of the MROM on the LGC board. (7) Check the version of the SROM on the SLG board. (8) Replace the SYS board. (9) Replace the SLG board. (10) Replace the LGC board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.