Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Description: Developing unit CRUM trouble (Magenta)
Causes: CRUM read/write error
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Description: Developing unit CRUM trouble (Yellow)
Causes: CRUM read/write error
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Description: Trouble of image density sensor for registration (Transfer belt surface reflection ratio abnormality)
Causes: Before starting registration, the transfer belt surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the value is not within the specified range.
Remedy: Case 1 Cause Image density sensor trouble, disconnection of the harness between the PCU PWB and the image density sensor, dirt on the image density sensor. Check & Remedy Check the sensor and the harness. Case 2 Cause Calibration plate solenoid operation trouble Check & Remedy Check the calibration plate solenoid operation. Case 3 Cause Insufficient cleaning of the transfer belt. Check & Remedy Check the transfer belt surface.
Description: Half-tone process control 1st batch trouble (Black)
Causes: First step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Description: Half-tone process control 1st batch trouble (Cyan)
Causes: First step operation error during half-tone process control
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.