Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp ARC260S — Trang 2/15

Code: E7 23

Description: LED controller initial trouble (Yellow)
Causes: The initial process of the LED controller cannot be completed properly.
Remedy: Case 1 Cause Disconnection of the LED head connector Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.

Code: E7 24

Description: LED controller output trouble (Black)
Causes: When printing, the print end signal for each page is not properly provided
Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.

Code: E7 25

Description: LED controller output trouble (Cyan)
Causes: When printing, the print end signal for each page is not properly provided.
Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.

Code: E7 26

Description: LED controller output trouble (Magenta)
Causes: When printing, the print end signal for each page is not properly provided.
Remedy: Case 1 Cause Disconnection of the LED head connector. Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit. Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.

Code: E7 27

Description: LED controller output trouble (Yellow)
Causes: When printing, the print end signal for each page is not properly provided.
Remedy: Case 1 Cause Disconnection of the LED head connector Check & Remedy Check connection of the LED head connector. Case 2 Cause Disconnection of the harness inside the LED head. Check & Remedy Replace the LED head unit Case 3 Cause ICU PWB abnormality Check & Remedy Replace the ICU PWB.

Code: E7 28

Description: LED control ASIC connection abnormality
Causes: Access error between the PCU PWB CPU and the LED control ASIC
Remedy: Case 1 Cause Disconnection of the ICU/ PCU PWB communication connector Check & Remedy Check connection of the ICU/PCU PWB communication connector Case 2 Cause ICU/PCU PWB communication harness trouble. Check & Remedy Check the ICU/PCU PWB communication harness. Case 3 Cause ICU PWB/PCU PWB trouble Check & Remedy Check grounding of the machine. Replace the IC

Code: E7 40

Description: Color correction data write error
Causes: Data write error to the Nand-Flash for holding color correction data
Remedy: Case 1 Cause Color correction data rewrite error Check & Remedy Perform rewriting of color correction data again. Case 2 Cause MFP PWB trouble Check & Remedy Replace the MFP PWB.

Code: E7 41

Description: Color correction data transfer abnormality
Causes: Data transfer error from the Nand-Flash for holding color correction data to the FC-RAM for holding color correction image process
Remedy: Replace the MFP PWB.