Description: Finisher tray lift motor trouble (Finisher detection)
Causes: Lift motor trouble
Remedy: Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 19
Description: Finisher front alignment motor trouble (Finisher detection)
Causes: Front alignment motor trouble
Remedy: Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 20
Description: Finisher rear alignment motor trouble (Finisher detection)
Causes: Rear alignment motor trouble
Remedy: Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 31
Description: Finisher fold sensor trouble
Causes: Sensor input value abnormality
Remedy: Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 32
Description: Finisher punch unit communication trouble
Causes: Communication error between the console finisher and the punch unit
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness of the console finisher and the punch unit. Check & Remedy Check the connector and the harness of the communication line. Case 2 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB. Case 3 Cause Console finisher control PWB trouble Check & Remedy Replace the console finisher control PWB. Case 4 Cause Malfunction by noises Check & Remedy Common Cancel method Can be canceled by turning OFF/ON the power.
Code: F1 33
Description: Finisher punch side registration motor trouble
Causes: Punch side registration motor operation trouble
Remedy: Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 34
Description: Finisher punch motor trouble
Causes: Punch motor operation trouble
Remedy: Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the staple motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.
Code: F1 35
Description: Finisher punch side registration sensor trouble
Causes: Sensor input value abnormality
Remedy: Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.