Description: Finisher front alignment motor trouble Front alignment motor operation abnormality
Causes: Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor. Home position sensor abnormality Motor rpm abnormality Finisher control PWB trouble
Remedy: Use SIM3-3 to check the motor operation.
Code: F1-19
Description: Console finisher front alignment motor trouble Front alignment motor operation abnormality
Causes: Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
Remedy: Use SIM3-3 to check the motor operation.
Code: F1-20
Description: Finisher rear alignment motor trouble Rear alignment motor operation abnormality
Causes: Motor lock Drive abnormality Defective connection or disconnection between the PWB and the motor. Home position sensor abnormality Motor rpm abnormality Finisher control PWB trouble
Remedy: Use SIM3-3 to check the motor operation.
Code: F1-20
Description: Console finisher rear alignment motor trouble Rear alignment motor operation abnormality
Causes: Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
Remedy: Use SIM3-3 to check the motor operation.
Code: F1-30
Description: Console finisher communication trouble Communication cable test error after turning on the power or exiting from SIM. Communication error with the console finisher
Causes: Improper connection or disconnection of connector and harness between the machine and the console finisher. Console finisher control PWB trouble Control PWB (PCU) trouble Malfunction by noises
Remedy: Canceled by turning OFF/ON the power. Check connectors and harness in the communication line. Replace the console finisher control PWB or PCU PWB.
Code: F1-31
Description: Console finisher fold sensor trouble Sensor input value abnormality
Causes: Sensor breakage harness breakage Console finisher control PWB trouble
Remedy: Use SIM3-2 to check the sensor operation.
Code: F1-32
Description: Communication trouble between the console finisher and the punch unit.
Causes: Improper connection or disconnection of connector and harness between the console finisher and the punch unit. Console finisher control PWB trouble Control PWB (PCU) trouble Malfunction by noise
Remedy: Canceled by turning OFF/ON the power. Check connectors and harness in the communication line. Replace the console finisher control PWB.
Code: F1-33
Description: Console finisher punch side registration motor trouble Punch side registration motor operation abnormality
Causes: Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble