Description: Fusing section high temperature trouble. The fusing temperature exceeds 242°C. (An input voltage of 0.27V or above is detected.)
Causes: thermistor trouble Control PWB trouble Fusing section connector disconnection AC power trouble
Remedy: Use DIAG (SIM5-2) to check the heater lamp Blinking operation. If the heater lamp blinks normally: Check the thermistor and its harness. Check the thermistor input circuit in the control PWB. If the heater lamp keep lighting: Check the AC PWB and the lamp control circuit in the control PWB. Use DIAG (SIM14) to cancel the trouble
Description: Fusing section high temperature trouble. The fusing temperature exceeds 242°C. (An input voltage of 0.27V or above is detected.)
Causes: thermistor trouble Control PWB trouble Fusing section connector disconnection AC power trouble
Remedy: Use DIAG (SIM5-2) to check the heater lamp Blinking operation. If the heater lamp blinks normally: Check the thermistor and its harness. Check the thermistor input circuit in the control PWB. If the heater lamp keep lighting: Check the AC PWB and the lamp control circuit in the control PWB. Use DIAG (SIM14) to cancel the trouble
Description: Fusing section low temperature trouble. •The set temperature is not reached within the specified time (normally 3 min) when warming up or resetting from pre-heating. •Under the ready state. (An input voltage of 1.21V or below is detected 5 times continuously.)
Causes: thermistor trouble Heater lamp trouble Control PWB trouble Thermostat trouble AC power trouble Interlock switch trouble
Remedy: Use DIAG (SIM5-2) to check the heater lamp Blinking operation. If the heater lamp blinks normally: Check the thermistor and its harness. Check the thermistor input circuit in the control PWB. If the heater lamp does not light: Check for heater lamp disconnection and thermostat disconnection. Check the interlock switch. Check the AC PWB and the lamp control circuit in the control PWB. Use DIAG (SIM14) to cancel the trouble.
Description: Fusing section low temperature trouble. •The set temperature is not reached within the specified time (normally 3 min) when warming up or resetting from pre-heating. •Under the ready state. (An input voltage of 1.21V or below is detected 5 times continuously.)
Causes: thermistor trouble Heater lamp trouble Control PWB trouble Thermostat trouble AC power trouble Interlock switch trouble
Remedy: Use DIAG (SIM5-2) to check the heater lamp Blinking operation. If the heater lamp blinks normally: Check the thermistor and its harness. Check the thermistor input circuit in the control PWB. If the heater lamp does not light: Check for heater lamp disconnection and thermostat disconnection. Check the interlock switch. Check the AC PWB and the lamp control circuit in the control PWB. Use DIAG (SIM14) to cancel the trouble.
Description: 5-time continuous POD1 not-reaching jam detection
Causes: A fusing section jam is not properly removed. (Jam paper remains.) POD1 sensor trouble, or harness disconnection Improper installation of fusing unit
Remedy: Check jam paper in the fusing section. (winding, etc.) Check POD1 sensor harness, and check installation the fusing unit. Use DIAG (SIM14) to cancel the trouble.
Description: Polygon motor lock detection. It is judged that the polygon motor lock signal is not outputted. Lock signal is checked in the interval of 10sec after starting the polygon motor, and it is judged that the polygon motor does not rotate normally.
Causes: The LSU connector or harness in the LSU is disconnected or broken. Polygon motor trouble
Remedy: Use DIAG (SIM61-1) to check the polygon motor operation. Check connector and harness connection. Replace LSU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.