Các lỗi thường gặp

Code :
  • Code: PC---
  • Description: Personal counter not installed
    The personal counter is not installed.
  • Causes: The personal counter is not installed.
  • Remedy: Install the personal counter.
  • Code: U1-01
  • Description: Battery trouble
    Backup SRAM battery voltage fall
  • Causes: 1) Battery life 2) Battery circuit abnormality
  • Remedy: Check that the battery voltage is about 2.5V or above.
  • Code: U2-00
  • Description: EEPROM read/write error (MFP detection)
    EEPROM device read/write error
  • Causes: EEPROM device trouble EEPROM device contact failure Device access error due to electrical noises
  • Remedy: Case 1 Cause EEPROM device trouble Check and remedy Replace the EEPROM device. Case 2 Cause EEPROM device contact failure Check and remedy Check that EEPROM device is properly inserted. Case 3 Cause Device access error due to electrical noises Check and remedy Replace the MFPcnt PWB.
  • Code: U2-05
  • Description: HDD/Flash/EEPROM data discrepancy
    A HDD or Flash memory for user authentication different from that used before turn off the power is installed.
  • Causes: Initialize the authentication information with SIM16, and import the backup data (exported data) if any.
  • Remedy: Initialize the authentication information with SIM16, and import the backup data (exported data) if any.
  • Code: U2-10
  • Description: SRAM user authentication index check sum error
    User index information (basic data of user authentication) check sum error on the SRAM
  • Causes: 1) SRAM trouble 2) Hang-up of the control circuit due to electrical noises 3) MFPcnt PWB SRAM access circuit trouble
  • Remedy: Use SIM16 to cancel U2 trouble.
  • Code: U2-11
  • Description: EEPROM check sum error (MFP detection)
    Counter information check sum error on the EEPROM
  • Causes: 1) EEPROM device trouble 2) EEPROM device contact failure 3) Device access error due to electrical noises
  • Remedy: Use SIM16 to cancel U2 trouble.
  • Code: U2-22
  • Description: SRAM memory check sum error
    MFPcnt PWB SRAM memory check sum error
  • Causes: SRAM trouble Control circuit hang-up due to electrical noises MFPcnt PWB SRAM access circuit trouble
  • Remedy: Case 1 Cause SRAM trouble Check and remedy 1) Initialize the communication management table registered in SRAM and the FAX soft switch. 2) Since the registered contents have been deleted, register them again. Case 2 Cause Control circuit hang-up due to electrical noises Check and remedy Use SIM16 to cancel U2 trouble. Case 3 Cause MFPcnt PWB SRAM access circuit trouble Check and remedy Replace the MFPcnt PWB.
  • Code: U2-23
  • Description: MFPC section SRAM memory individual data check sum error
    MFPcnt PWB SRAM memory individual data check sum error (Communication management table, sender registration data, etc.)
  • Causes: SRAM trouble Control circuit hang-up due to electrical noises MFPcnt PWB SRAM access circuit trouble
  • Remedy: Case 1 Cause SRAM trouble Check and remedy 1) Turn OFF/ON the power to initialize the data related to the check sum error automatically. 2) Since the registered contents have been deleted, register them again. Case 2 Cause Control circuit hang-up due to electrical noises Check and remedy Use SIM16 to cancel U2 trouble. Case 3 Cause MFPcnt PWB SRAM access circuit trouble Check and remedy Replace the MFPcnt PWB.
‹ First  < 14 15 16 17 18 19 20 > 