Các lỗi thường gặp

Code :
  • Code: E7-55
  • Description: PWB information sum error (Engine detection)
    EEPROM PWB information sum error
  • Causes: 1) EEPROM device error 2) EEPROM device contact failure 3) Device access error due to noises
  • Remedy: Replace the PCU PWB.
  • Code: E7-60
  • Description: Controller connection trouble (Engine detection)
    Unknown PWB kind information is detected in the MFPcnt PWB. A PWB/firmware which is not compatible with the machine specifications is connected.
  • Causes: Controller PWB trouble A firmware which is not compatible with the machine specifications is applied.
  • Remedy: Case 1 Cause Controller PWB trouble Check and remedy Replace the controller PWB. Case 2 Cause A firmware which is not compatible with the machine specifications is applied. Check and remedy Check the kind and the version of the firmware.
  • Code: E7-61
  • Description: Controller connection trouble (Engine)
    MFPcnt PWB connection trouble Compatibility trouble between the controller and the engine
  • Causes: Combination trouble of the controller PWB and the engine
  • Remedy: Check the controller PWB. Check the combination between the controller PWB and the engine.
  • Code: E7-62
  • Description: Controller connection trouble (Scanner)
    Controller connection trouble Compatibility trouble between the controller and the scanners
  • Causes: Combination trouble between the controller PWB and the engine
  • Remedy: Replace the controller PWB. Check the combination between the controller PWB and the engine.
  • Code: E7-65
  • Description: PWB information sum error (Controller detection)
    EEPROM PWB information sum error
  • Causes: 1) EEPROM device trouble 2) EEPROM device contact failure 3) Device access error due to noises
  • Remedy: Replace the MFPcnt PWB.
  • Code: E7-70
  • Description: Scanner connection trouble
    Unknown identification information is detected in the SCU PWB.
  • Causes: SCU PWB trouble A firmware which is incompatible with the machine
    specifications is connected.
  • Remedy: Case 1 Cause SCU PWB trouble Check and remedy Replace the SCU PWB. Case 2 Cause A firmware which is incompatible with the machine specifications is connected. Check and remedy Check the kind and the version of the firmware.
  • Code: E7-75
  • Description: PWB information sum error (Scanner detection)
    EEPROM PWB information sum error
  • Causes: 1) EEPROM device trouble 2) EEPROM device contact failure 3) Device access error due to noises
  • Remedy: Replace the scanner control PWB.
  • Code: E7-80
  • Description: Communication trouble between the controller and the scanner
    Communication trouble between the MFP and the scanner MFP detection Communication establishment error/Framing/Parity/ Protocol error
  • Causes: SCU PWB connector connection trouble Harness trouble between the SCU PWB and the MFPcnt PWB Broken connector pin of the SCU PWB mother board
  • Remedy: Case 1 Cause SCU PWB connector connection trouble Check and remedy Check the connector connection between the SCU PWB and the MFPcnt PWB. Case 2 Cause Harness trouble between the SCU PWB and the MFPcnt PWB Check and remedy Check the harness between the SCU PWB and the MFPcnt PWB. Case 3 Cause Broken connector pin of the SCU PWB mother board Check and remedy Check grounding of the machine.