Code: F2-70

Description: Improper toner cartridge detection (BLACK)
Causes: An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble
Remedy: Replace the toner cartridge. Replace the PCU PWB.

Code: F2-71

Description: Improper toner cartridge detection (CYAN)
Causes: An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB.

Code: F2-72

Description: Improper toner cartridge detection (MAGENTA)
Causes: An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB.

Code: F2-73

Description: Improper toner cartridge detection (YELLOW)
Causes: An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB.

Code: F2-74

Description: Toner cartridge CRUM error (BLACK)
Causes: Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.

Code: F2-75

Description: Toner cartridge CRUM error (CYAN)
Causes: Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.

Code: F2-76

Description: Toner cartridge CRUM error (MAGENTA)
Causes: Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.

Code: F2-77

Description: Toner cartridge CRUM error (YELLOW)
Causes: Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy: Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.