Description: Toner cartridge improper cartridge detection (BLACK) Improper data are detected in the CRUM contents when the normal CRUM of the cartridge is detected.
Causes: An improper cartridge is inserted. Toner cartridge trouble
Description: Toner cartridge improper cartridge detection (CYAN) Improper data are detected in the CRUM contents when the normal CRUM of the cartridge is detected.
Causes: An improper cartridge is inserted. Toner cartridge trouble
Description: Toner cartridge improper cartridge detection (MAGENTA) Improper data are detected in the CRUM contents when the normal CRUM of the cartridge is detected.
Causes: An improper cartridge is inserted. Toner cartridge trouble
Description: Toner cartridge improper cartridge detection (YELLOW) Improper data are detected in the CRUM contents when the normal CRUM of the cartridge is detected.
Causes: An improper cartridge is inserted. Toner cartridge trouble
Description: Toner cartridge CRUM error (BLACK) CRUM cannot be read or written.
Causes: Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. CRUM trouble Control PWB (PCU) trouble
Remedy: Case 1 Cause Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. Check and remedy Check the connector and the harness between the PCU and the toner cartridge. Case 2 Cause CRUM trouble Check and remedy Replace the toner cartridge. Case 3 Cause Control PWB (PCU) trouble Check and remedy Replace the PCU PWB.
Description: Toner cartridge CRUM error (CYAN) CRUM cannot be read or written.
Causes: Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. CRUM trouble Control PWB (PCU) trouble
Remedy: Case 1 Cause Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. Check and remedy Check the connector and the harness between the PCU and the toner cartridge. Case 2 Cause CRUM trouble Check and remedy Replace the toner cartridge. Case 3 Cause Control PWB (PCU) trouble Check and remedy Replace the PCU PWB.
Description: Toner cartridge CRUM error (MAGENTA) CRUM cannot be read or written.
Causes: Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. CRUM trouble Control PWB (PCU) trouble
Remedy: Case 1 Cause Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. Check and remedy Check the connector and the harness between the PCU and the toner cartridge. Case 2 Cause CRUM trouble Check and remedy Replace the toner cartridge. Case 3 Cause Control PWB (PCU) trouble Check and remedy Replace the PCU PWB.
Description: Toner cartridge CRUM error (YELLOW) CRUM cannot be read or written.
Causes: Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. CRUM trouble Control PWB (PCU) trouble
Remedy: Case 1 Cause Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. Check and remedy Check the connector and the harness between the PCU and the toner cartridge. Case 2 Cause CRUM trouble Check and remedy Replace the toner cartridge. Case 3 Cause Control PWB (PCU) trouble Check and remedy Replace the PCU PWB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.