Causes: 1) Pin getting away of a harness (2TC-ERR) and breaking (TC PWB Input connector CN1-3pin) 2) High-voltage error circuit (2TC-ERR) damage
Remedy: 1) Check connection of the harness.(TC PWB Input connector CN1-3pin) Replace the harness. 2) Check disconnection of the high voltage TC PWB connector./Replace.
Code: C4-40
Description: High-voltage TC PWB trouble
Causes: 1) Input harness disconnection in the high voltage TC PWB. 2) Harness (1TC-ERR, 2TC-ERR, PTC-ERR) pin disconnection 3) 24V fuse meltdown in the high voltage TC PWB 4) High voltage error circuit (1TC-ERR, 2TC-ERR, PTC-ERR) breakage in the high voltage TC PWB
Remedy: 1) Check the harness and the connector (TC PWB Input connector CN1) 2) Check or replace the harness.(TC PWB input connector CN1-2pin, CN1-3pin, CN1-4pin) 3) 4) Replace the MC PWB
Causes: Installation error of the CCD unit harness. Copy lamp lighting trouble. Dirt on the mirror, the lens or the reference white plate. CCD unit trouble. DSPF PWB trouble. Shading correction not executed.
Remedy: Check the installing state of the harness the CCD unit. Check the installing state of the harness to the copy lamp unit. Clean the mirror, the lens or the reference plate. Check the CCD unit. Check the DSPF PWB.
Code: E6-14
Description: CCD ASIC error (SPF)
Causes: DSPF PWB trouble
Remedy: Check the DSPF PWB
Code: E7-01
Description: SCN-MFP image data error
Causes: Image data transfer error in the SCN-MFP PWB. SCN-MFP PWB trouble.
Remedy: Check connection of the connector and the harness of the SCN-MFP PWB. Check or replace the SCN-MFP PWB.
Code: E7-03
Description: HDD trouble / Mirroring kit error
Causes: Connector, harness connection trouble in the SCNMFP PWB and HDD. HDD (error file management area) data abnormality (FAT breakage). SCN-MFP PWB trouble. Break down HDD HDD connector trouble error file management area data abnormality (FAT breakage) HDD is not set normally. SCN-MFP PWB trouble
Remedy: Check connection of the connector and the harness of the SCN-MFP PWB and HDD. Use SIM62-2, 3 to check read/write operations of the HDD. Replace the HDD. Check or replace the SCN-MFP PWB.