Các lỗi thường gặp

Code :
  • Code: F1-39
  • Description: Finisher punch dust sensor trouble (MX-FNX2)
    Punch dust sensor detection trouble
  • Causes: Sensor breakage, harness disconnection, finisher control PWB trouble (MX-FNX2), punch control PWB trouble (MX-FNX2)
  • Remedy: Use SIM3-2 to check the operation of the sensor punch dust sensor (FPDD). Replace the finisher control PWB or the punch control PWB.
  • Code: F1-40
  • Description: Saddle finisher punch power interruption trouble (MX-FNX2)
    When the punch unit power interruption is detected.
  • Causes: Harness disconnection, punch control PWB trouble
  • Remedy: Use SIM3-3 to check the operation punch motor (FPNW). Replace the finisher punch unit (Replace the punch control PWB.).
  • Code: F1-50
  • Description: Finisher incompatibility trouble
    Detection of finisher incompatible with MX-3500**/ 4500**/3501**/4501**
  • Causes: Connection of the AR-F13, etc. which is incompatible with MX-3500**/4500**/3501**/4501** is detected.
  • Remedy: Connect the MX-FNX1/MX-FNX2.
  • Code: F2-39
  • Description: Process thermistor trouble
    Process thermistor open
  • Causes: Process thermistor harness connection trouble Process thermistor trouble PCU PWB trouble
  • Remedy: Check the PCU PWB.
  • Code: F2-40
  • Description: Toner empty sensor abnormality (BLACK)
    Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
  • Causes: The connector is not installed. Connector harness trouble Cartridge trouble
  • Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.
  • Code: F2-41
  • Description: Toner empty sensor abnormality (CYAN)
    Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
  • Causes: The connector is not installed. Connector harness trouble Cartridge trouble
  • Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.
  • Code: F2-42
  • Description: Toner empty sensor abnormality (MAGENTA)
    Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
  • Causes: The connector is not installed. Connector harness trouble Cartridge trouble
  • Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.
  • Code: F2-43
  • Description: Toner empty sensor abnormality (YELLOW)
    Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
  • Causes: The connector is not installed. Connector harness trouble Cartridge trouble
  • Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.