Các lỗi thường gặp

Code :
  • Code: E7-25
  • Description: LSU LD driver error (C)
  • Causes: Reduced laser power, lighting error, laser diode trouble. LSU connector trouble. LSU PWB trouble.
  • Remedy: Use SIM61-1 to check the operation of the LSU. Check the LSU PWB. Check connection of the LSU connector. Replace the LSU.
  • Code: E7-26
  • Description: LSU LD driver error (M)
  • Causes: Reduced laser power, lighting error, laser diode trouble. LSU connector trouble. LSU PWB trouble.
  • Remedy: Use SIM61-1 to check the operation of the LSU. Check the LSU PWB. Check connection of the LSU connector. Replace the LSU.
  • Code: E7-27
  • Description: LSU LD driver error (Y)
  • Causes: Reduced laser power, lighting error, laser diode trouble. LSU connector trouble. LSU PWB trouble.
  • Remedy: Use SIM61-1 to check the operation of the LSU. Check the LSU PWB. Check connection of the LSU connector. Replace the LSU.
  • Code: E7-28
  • Description: LSU - PCU connection error
  • Causes: Communication error between the CPU in the PCU PWB and the LSU PWB ASIC. Improper connection of the communication connector between the PCU PWB and the LSU PWB. Harness trouble between the PCU PWB and the LSU PWB. PCU PWB trouble. LSU control PWB trouble. LSU trouble. LSU mother PWB trouble.
  • Remedy: Check connection of the connector and the harness between the PCU PWB and the LSU PWB. Check the LSU PWB. Replace the PCU PWB. Replace the LSU.
  • Code: E7-29
  • Description: LSU ASIC frequency error
  • Causes: Oscillation abnormality of the external oscillator used in the LSU ASIC. LSU ASIC abnormality on the LSU PWB. Frequency abnormality of picture transfer clock of SCN-MFP PWB.
  • Remedy: Check the LSU PWB. Check connection of the connector and the harness between the SCN-MFP PWB and the LSU PWB.
  • Code: E7-42
  • Description: Image data trouble (Scanner expansion PWB (ACRE) ASIC)
  • Causes: An image data error occurs. An image data send error occurs. Scanner expansion PWB (ACRE) connection trouble. Scanner expansion PWB (ACRE) trouble. SCN-MFP PWB trouble.
  • Remedy: Check connection of the scanner expansion PWB (ACRE). Check the scanner expansion PWB (ACRE), and replace if necessary. Check the SCN-MFP PWB, and replace if necessary.
  • Code: E7-46
  • Description: Image data decode error (Scanner expansion PWB (ACRE) ASIC)
  • Causes: A decode error occurs while high compression PDF images are made. (garbled data) Scanner expansion PWB (ACRE) connection trouble. Scanner expansion PWB (ACRE) trouble. SCN-MFP PWB trouble
  • Remedy: Check connection of the scanner expansion PWB (ACRE). Check the scanner expansion PWB (ACRE), and replace if necessary. Check the SCN-MFP PWB, and replace if necessary
  • Code: E7-47
  • Description: Combination of firmware error between the SCN-MFP and the ACRE ASIC
  • Causes: Written ACRE board of the firmware that a model did not support MFP was connected.
  • Remedy: Check the kind and the version of the firmware. Use SIM49-1 or SIM49-10 to execute firmware version-up