Causes: Contact trouble between the discharge lamp PWB (Y) and the PCU PWB. Discharge lamp PWB (Y) trouble. PCU PWB trouble.
Remedy: Use SIM5-4 to check the operation of the discharge lamp on. Replace the discharge lamp PWB (Y). Check the harness and the connector. Replace the PCU PWB.
Code: F2-39
Description: Temperature/humidity sensor trouble (Indoor temperature detection trouble)
Causes: Detection of abnormality by the temperature sensor on internal temperature/ humidity sensor PCU PWB trouble.
Remedy: Check internal temperature/humidity sensor and check the connection of harness and connector. Check the PCU PWB.
Code: F2-40
Description: Toner density sensor trouble (K)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-41
Description: Toner density sensor trouble (C)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-42
Description: Toner density sensor trouble (M)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-43
Description: Toner density sensor trouble (Y)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-45
Description: Color image density sensor trouble
Causes: Image density sensor trouble. Image density sensor harness and PCU PWB connector connection trouble. Image density sensor dirt. Transfer belt cleaning trouble.
Remedy: Use SIM44-6 to execute the process control. Clean the image density sensor. Replace the image density sensor.
Code: F2-49
Description: LSU thermistor trouble
Causes: The LSU temperature is outside of -28C - 78C. LSU thermistor trouble. LSU thermistor harness and connector connection trouble PCU PWB trouble. LSU PWB trouble.
Remedy: Check the harness and the connector connection at LSU thermistor. Replace the PCU PWB. Replace the LSU.