Các lỗi thường gặp

Code :
  • Code: U2-81
  • Description: SCU PWB EEPROM check sum error
  • Causes: SCU PWB EEPROM trouble. Installation of non-initialized EEPROM. SCU PWB trouble. EEPROM socket contact trouble.
  • Remedy: Replace the SCU PWB EEPROM. Replace the SCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.
  • Code: U2-90
  • Description: PCU PWB EEPROM read/write error
  • Causes: PCU PWB EEPROM trouble. Installation of non-initialized EEPROM. PCU PWB trouble EEPROM socket contact trouble.
  • Remedy: Replace the PCU PWB EEPROM. Replace the PCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.
  • Code: U2-91
  • Description: PCU PWB EEPROM check sum error
  • Causes: PCU PWB EEPROM trouble. Installation of non-initialized EEPROM. PCU PWB trouble EEPROM socket contact trouble.
  • Remedy: Replace the PCU PWB EEPROM. Replace the PCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.
  • Code: U5-00
  • Description: Document feed unit communication error
  • Causes: Connector, harness connection trouble. SCU PWB trouble. DSPF PWB trouble.
  • Remedy: Turn OFF/ON the power. Check connection of the connector and the harness. Replace the SCU PWB. Replace the DSPF PWB.
  • Code: U5-16
  • Description: Document feed unit fan trouble
  • Causes: When the fan is operated, the fan operation signal is not detected within the specified time. Fan motor trouble. Connector, harness connection trouble. DSPF PWB trouble.
  • Remedy: Use SIM2-3 to check that the fan is rotating. Replace the fan motor. Check connection of the connector and the harness. Replace the DSPF PWB.
  • Code: U5-30
  • Description: Document feed unit tray lift up trouble
  • Causes: When STUD is not turned ON 5 times continuously within the specified time. STUD/STLD sensor trouble. Connection trouble of the connector and the harness. Replace the DSPF PWB.
  • Remedy: Replace the STUD/STLD sensor. Check connection of the connector and the harness. Replace the DSPF PWB.
  • Code: U5-31
  • Description: Document feed unit tray lift down trouble
  • Causes: STLD does not turn OFF within the specified time. STUD/STLD sensor trouble. Connection trouble of the connector and the harness. Replace the DSPF PWB.
  • Remedy: Replace the STUD/STLD sensor. Check connection of the connector and the harness. Replace the DSPF PWB.
  • Code: U5-40
  • Description: Document feed unit installation trouble
  • Causes: When two or more document feed units are detected. Connection trouble of the connector and the harness. Document feeder trouble.
  • Remedy: Check connection of the connector and the harness.