Description: Paper feed tray 1 lift operation trouble
Causes: LUD1 is not turned ON within the specified time. CLUD1 sensor trouble. Paper feed tray 1 lift unit trouble. PCU PWB trouble. Sensor harness and connector connection trouble
Remedy: Check connection of the harness and the connector of LUD1. Replace the lift-up unit. Replace the PCU PWB.
Description: Paper feed tray 2 lift operation trouble LUD2 does not turn ON within the specified time
Causes: LUD2 does not turn ON within the specified time. CLUD2 sensor trouble. Paper feed tray 2 lift unit trouble. PCU PWB trouble. Sensor harness and connector connection trouble
Remedy: Check the harness and the connector of LUD2. Replace the lift-up unit. Replace the PCU PWB.
Description: MFPC PWB - FAX communication trouble MFP - FAX communication establishment error / Framing / Parity / Protocol error
Causes: FAX control PWB trouble. FAX control PWB - MFPC PWB connector and harness trouble FAX control PWB - Mother board connector and harness trouble FAX control PWB ROM trouble / ROM pin breakage
Remedy: Case 1 Cause FAX control PWB trouble. Check and Remedy Replace the FAX control PWB. Case 2 Cause FAX control PWB - MFPC PWB connector and harness trouble Check and Remedy Check the connector and the harness between the FAX control PWB and the MFPC PWB. Case 3 Cause FAX control PWB - Mother board connector and harness trouble Check and Remedy Check the connector and the harness between the FAX control PWB and the mother board. Case 4 Cause FAX control PWB ROM trouble / ROM pin breakage Check and Remedy Check the ROM of the FAX control PWB.
Description: FAX control PWB EEPROM read/write error FAX control PWB EEPROM access error (Read and write)
Causes: FAX control PWB EEPROM trouble FAX control PWB EEPROM access circuit trouble
Remedy: Case 1 Cause FAX control PWB EEPROM trouble Check and Remedy Check that no trouble occurs after replacement of EEPROM. Execute the memory check of SIM66-3 to insure that EEPROM can be accessed. Case 2 Cause FAX control PWB EEPROM access circuit trouble Check and Remedy Replace the FAX control PWB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.