Causes: Abnormality in the CCD black scan level when the scanner lamp is turned OFF. Improper installation of the harness to the CCD unit. CCD unit abnormality. SCU PWB abnormality.
Remedy: Check connection of the harness to the CCD unit. Check the CCD unit. Check the SCU PWB.
Causes: Abnormality in the CCD white reference plate scan level when the scanner lamp is turned ON. Improper installation of the harness to the CCD unit. Dirt on the mirror, lens, and the reference white plate. Scanner lamp lighting trouble. Scanner lamp drive PWB trouble CCD unit abnormality. SCU PWB abnormality.
Remedy: Check connection of the harness to the CCD unit. Check connection of the harness to the scanner lamp unit. Check or replace the scanner lamp. Check or replace the scanner lamp drive PWB. Clean or replace the mirror, the lens, and the reference white board. Check or replace the CCD unit. Check or replace the SCU PWB.
Causes: When lighting the LSU LD, initialization of the LD driver is not performed normally. Harness/connector trouble between the LD PWB and the LSU mother PWB. LD PWB trouble. LSU mother PWB trouble.
Remedy: Use SIM61-1 to check the operation of the LSU. Check the LSU, and replace if necessary. Check the LSU mother PWB, and replace if necessary. Check connection of the harness/connector between the LD PWB and the LSU mother PWB.