Code: F1-39

Description: Finisher punch dust sensor trouble (MX-FNX2)
Punch dust sensor detection trouble
Causes: Sensor breakage, harness disconnection, finisher control PWB trouble (MX-FNX2), punch control PWB trouble (MX-FNX2)
Remedy: Use SIM3-2 to check the operation of the sensor punch dust sensor (FPDD). Replace the finisher control PWB or the punch control PWB.

Code: F1-40

Description: Saddle finisher punch power interruption trouble (MX-FNX2)
When the punch unit power interruption is detected.
Causes: Harness disconnection, punch control PWB trouble
Remedy: Use SIM3-3 to check the operation punch motor (FPNW). Replace the finisher punch unit (Replace the punch control PWB.).

Code: F1-50

Description: Finisher incompatibility trouble
Detection of finisher incompatible with MX-3500**/ 4500**/3501**/4501**
Causes: Connection of the AR-F13, etc. which is incompatible with MX-3500**/4500**/3501**/4501** is detected.
Remedy: Connect the MX-FNX1/MX-FNX2.

Code: F2-39

Description: Process thermistor trouble
Process thermistor open
Causes: Process thermistor harness connection trouble Process thermistor trouble PCU PWB trouble
Remedy: Check the PCU PWB.

Code: F2-40

Description: Toner empty sensor abnormality (BLACK)
Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
Causes: The connector is not installed. Connector harness trouble Cartridge trouble
Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.

Code: F2-41

Description: Toner empty sensor abnormality (CYAN)
Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
Causes: The connector is not installed. Connector harness trouble Cartridge trouble
Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.

Code: F2-42

Description: Toner empty sensor abnormality (MAGENTA)
Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
Causes: The connector is not installed. Connector harness trouble Cartridge trouble
Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.

Code: F2-43

Description: Toner empty sensor abnormality (YELLOW)
Toner empty sensor output abnormality. Sample level 25 or less or 231 or above.
Causes: The connector is not installed. Connector harness trouble Cartridge trouble
Remedy: Case 1 Cause The connector is not installed. Check and remedy Check the connection of the connector harness to the PCU PWB. Check the connection of the toner empty sensor. Case 2 Cause Connector harness trouble Check and remedy Check the harness disconnection. Case 3 Cause Cartridge trouble Check and remedy Check the cartridge connection.