Code :
  • Code: U5-30
  • Description: SPF lift-up trouble
    Lift-up trouble is detected 5 times continuously. (MX-3501N/4501N)
  • Causes: STUD/STLD trouble
  • Remedy: Check STUD/STLD and its harness and connector. Check the lift-up unit.
  • Code: U5-31
  • Description: SPF tray lift-down trouble
    Lift-down trouble (STLD does not turn OFF within the specified time.) (MX-3501N/4501N)
  • Causes: STUD/STLD trouble
  • Remedy: Check STUD/STLD and its harness and connector. Check the lift-up unit.
  • Code: U5-40
  • Description: SPF install trouble
    Detected the installed (individual installed signal ) of RSPF/DSPF both.
  • Causes: Circuit trouble of the installed detection signal
  • Remedy: Check installed detection circuit and harness, connector.
  • Code: U6-00
  • Description: Desk communication trouble
    Desk communication error, communication line test error after turning on the power or canceling the exclusive simulation
  • Causes: Connector and harness connection trouble or disconnection, desk control PWB trouble, control PWB (PCU) trouble, malfunction due to electrical noises
  • Remedy: Cancel the trouble by turning OFF/ON. Check the connector and the harness of the communication line.
  • Code: U6-01
  • Description: Tray 1 lift-up trouble
    DLUD1 does not turn ON within the specified time.
  • Causes: DLUD1 sensor trouble, tray 1 lift-up motor trouble, desk PWB, lift-up unit, paper feed unit harness connection trouble
  • Remedy: Check DLUD1 and its harness and connector. Check the lift-up unit.
  • Code: U6-02
  • Description: Tray 2 lift-up trouble
    DLUD2 does not turn ON within the specified time
  • Causes: DLUD2 sensor trouble, tray 2 lift-up motor trouble, desk PWB, lift-up unit, paper feed unit harness connection trouble
  • Remedy: Check DLUD2 and its harness and connector. Check the lift-up unit.
  • Code: U6-09
  • Description: LCC lift motor trouble
    • The encoder input value is not changed in 0.13sec (1st time)/0.5sec (2nd time and later) after rotation of the motor. • The motor is rotated for 18sec or more. • The encoder is changed after passing a certain time from stopping the motor. (2sec, 10 count or more)
  • Causes: Sensor trouble, LCC control PWB trouble, gear breakage, lift motor trouble
  • Remedy: Use SIM4-2 and 4-3 to check the operation of the sensor and the lift motor. Use SIM15 to cancel the trouble.
  • Code: U6-10
  • Description: Desk transport motor trouble
    Desk transport motor operation trouble
  • Causes: Motor lock, motor RPM abnormality, overcurent to the motor, console finisher control PWB trouble