Description: Fusing low temperature recovery trouble (TH_UM_AD2).
Causes: The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy: Replace the thermistor. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: H7-11
Description: Fusing low temperature recovery trouble (TH_LM)
Causes: The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy: Replace the thermistor. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: H7-12
Description: Fusing low temperature recovery trouble (TH_US)
Causes: The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy: Replace the thermistor. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: H7-14
Description: Recovery error from low fuser temp. (TH_EX)
Causes: The specified temperature is not reached within the specified time from job stop due to a fall in the fusing temperature. Thermistor trouble. Thermostat trouble. Heater lamp trouble. PCU PWB trouble. Power unit trouble. Interlock switch trouble. Connection trouble of the connector and the harness.
Remedy: Replace the thermistor. Replace the thermostat. Replace the heater lamp. Replace the PCU PWB. Replace the power unit. Replace the interlock switch. Check connection of the connector and the harness. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: L1-00
Description: Scanner feed trouble
Causes: Scanner feed is not completed within the specified time. Scanner unit trouble. SCU PWB trouble Scanner control PWB trouble. Harness and connector connection trouble. Scanner home position sensor trouble. Scanner motor trouble.
Remedy: Use SIM1-1 to check the scan operation. Replace the scanner unit. Replace the SCU PWB. Check connection of the connectors and the harness. Replace the scanner home position sensor. Replace the scanner motor.
Code: L3-00
Description: Scanner return trouble
Causes: Scanner return is not completed within the specified time. Scanner unit trouble. SCU PWB trouble Scanner control PWB trouble. Harness and connector connection trouble. Scanner home position sensor trouble. Scanner motor trouble.
Remedy: Use SIM1-1 to check the scan operation. Replace the scanner unit. Replace the SCU PWB. Check connection of the connectors and the harness. Replace the scanner home position sensor. Replace the scanner motor.
Code: L4-02
Description: Paper feed motor trouble
Causes: The lock signal Is not detected within 1 sec when turning ON the paper feed motor when warming up, canceling a jam. Paper feed motor trouble. Harness and connector connection trouble. PCU PWB trouble
Remedy: Use SIM6-1 to check the operation of the paper feed motor. Replace the paper feed motor. Check connection of the connectors and the harness. Replace the PCU PWB.
Code: L4-03
Description: Fusing motor trouble
Causes: The motor lock signal is detected during rotation of the fusing motor. Fusing motor trouble. Connection trouble of the connector and the harness. PCU PWB trouble.
Remedy: Use SIM6-1 to check the operation of the fusing motor. Replace the Fusing motor. Check connection of the connectors and the harness. Replace the PCU PWB.