Các lỗi thường gặp

Code :
  • Code: L4-31
  • Description: Paper exit cooling fan trouble
  • Causes: Paper exit cooling fan trouble. PCU PWB trouble Connection trouble of the connector and the harness.
  • Remedy: Check connection of the connectors and the harness. Use SIM6-2 to check the rotating operation of the fan. Replace the paper exit cooling fan. Replace the PCU PWB.
  • Code: L4-32
  • Description: Power source cooling fan trouble
  • Causes: Power cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM6-2 to check that the fan is actually rotating. Replace the power cooling fan. Replace the PCU PWB. Check connection of the connectors and the harness.
  • Code: L4-34
  • Description: LSU cooling fan trouble
  • Causes: When the LSU cooling fan is operated, the fan operation signal is not detected within the specified time. LSU fan trouble. Harness, connector trouble. LSU mother PWB trouble.
  • Remedy: Use SIM6-2 to check the fan operation. Check the LSU fan, and replace if necessary. Check the harness/connector, and replace if necessary. Check the LSU mother PWB, and replace if necessary.
  • Code: L4-35
  • Description: Fusing cooling fan trouble
  • Causes: Fusing cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM6-2 to check that the fan is actually rotating. Replace the fusing cooling fan. Replace the PCU PWB. Check connection of the connector and the harness
  • Code: L4-45
  • Description: Toner cooling fan trouble (Toner cooling fan 1, 2)
  • Causes: When the toner cooling fan is operated, the fan operation signal is not detected within the specified time. Toner cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: After turning ON the power, check to confirm that the fan is rotating. Replace the toner cooling fan. Replace the PCU PWB. Check connection of the connector and the harness.
  • Code: L4-50
  • Description: Process fan trouble
  • Causes: Process fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Check that the fan is rotating after turning ON the power. Replace the process fan. Replace the PCU PWB. Check connection of the connector and the harness.
  • Code: L4-56
  • Description: Rear cooling fan trouble
  • Causes: The fan operation signal is not detected within the specified time in the rear cooling fan operation. Rear cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Check that the fan is rotating after turning ON the power. Replace the rear cooling fan. Replace the PCU PWB. Check connection of the connector and the harness.
  • Code: L4-58
  • Description: Ozone exhaust fan trouble
  • Causes: The fan operation signal is not detected within the specified time in the ozone exhaust fan operation. Ozone exhaust fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Check that the fan is rotating after turning ON the power. Replace the ozone exhaust fan. Replace the PCU PWB. Check connection of the connector and the harness.