Các lỗi thường gặp

Code :
  • Code: U2-50
  • Description: HDD user authentication data check sum error
  • Causes: HDD trouble MFPC PWB trouble Strong external noises.
  • Remedy: Check the data related to the check sum error (address book, image send system registration data (senders record, meta data)) and register again. Use SIM16 to cancel the U2 trouble. Replace the HDD. Replace the MFPC PWB. (Refer to the pages on the necessary works after replacing the HDD and the MFPC PWB in the Service Manual, and perform the works.)
  • Code: U2-60
  • Description: Watermark check error
  • Causes: Watermark data trouble HDD trouble MFPC PWB trouble
  • Remedy: Use SIM16 to cancel the U2 trouble. Use SIM49-5 to install the watermark data. Replace the HDD. Replace the MFPC PWB. (Refer to the pages on the necessary works after replacing the HDD and the MFPC PWB in the Service Manual, and perform the works.)
  • Code: U2-80
  • Description: SCU PWB EEPROM read/write error
  • Causes: SCU PWB EEPROM trouble SCU PWB trouble SCU PWB EEPROM socket connection trouble
  • Remedy: Replace the SCU PWB EEPROM. Replace the SCU PWB. Check connection of the SCU PWB EEPROM socket. Check the SIM adjustment value of the following items, and adjust again if they are improper. Scanner-related adjustments Touch panel-related adjustments Use SIM16 to cancel the trouble.
  • Code: U2-81
  • Description: SCU PWB EEPROM check sum error
  • Causes: SCU PWB EEPROM trouble. Installation of non-initialized EEPROM. SCU PWB trouble. EEPROM socket contact trouble.
  • Remedy: Replace the SCU PWB EEPROM. Replace the SCU PWB. Check contact of the EEPROM socket. Use SIM16 to cancel the trouble. (The check sum error detection data are calculated again to reset the proper check sum data.)
  • Code: U2-90
  • Description: PCU PWB EEPROM read/write error
  • Causes: PCU PWB EEPROM trouble PCU PWB trouble EEPROM socket contact trouble
  • Remedy: Replace the PCU PWB EEPROM. Check the SIM adjustment values of the engine, and adjust again if they are improper. Replace the PCU PWB. Check contact of the EEPROM socket. Use SIM16 to cancel the trouble.
  • Code: U2-91
  • Description: PCU PWB EEPROM check sum error
  • Causes: PCU PWB EEPROM trouble PCU PWB trouble EEPROM socket contact trouble
  • Remedy: Replace the PCU PWB EEPROM. Replace the PCU PWB. Check contact of the EEPROM socket. Use SIM16 to cancel the trouble. (The check sum error detection data are calculated again to reset the proper check sum data.)
  • Code: U5-00
  • Description: Document feed unit communication error
  • Causes: Connector, harness connection trouble. SCU PWB trouble. DSPF PWB trouble.
  • Remedy: Turn OFF/ON the power. Check connection of the connector and the harness. Replace the SCU PWB. Replace the DSPF PWB.
  • Code: U5-16
  • Description: Document feed unit fan trouble
  • Causes: When the fan is operated, the fan operation signal is not detected within the specified time. Fan motor trouble. Connector, harness connection trouble. DSPF PWB trouble.
  • Remedy: Use SIM2-3 to check that the fan is rotating. Replace the fan motor. Check connection of the connector and the harness. Replace the DSPF PWB