Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-41
Description: Toner density sensor trouble (C)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-42
Description: Toner density sensor trouble (M)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB.
Code: F2-43
Description: Toner density sensor trouble (Y)
Causes: Toner density sensor output abnormality. Sensor connector and harness connection trouble. Developing unit trouble. PCU PWB trouble
Remedy: Replace the toner density sensor. Check connection of the sensor connector and the harness. Replace the developing unit. Replace the PCU PWB
Code: F2-45
Description: Color image density sensor trouble
Causes: Image density sensor trouble. Image density sensor harness and PCU PWB connector connection trouble. Image density sensor dirt. Transfer belt cleaning trouble
Remedy: Use SIM44-6 to execute the process control. Clean the image density sensor. Replace the image density sensor.
Code: F2-49
Description: LSU thermistor trouble
Causes: The LSU temperature is outside of -28..C - 78..C. LSU thermistor trouble. LSU thermistor harness and connector connection trouble PCU PWB trouble. LSUcnt PWB trouble. LD PWB trouble
Remedy: Check the harness and the connector connection at LSU thermistor. Replace the PCU PWB. Replace the LSU. Replace the LSUcnt PWB.
Remedy: Check the sensor condition and check the connection. Use SIM30-1 to check the operation of "DHPD_K". Replace the drum phase sensor. Repair the drum drive section. Replace the PCU PWB.
Remedy: Check the sensor condition and check the connection. Use SIM30-1 to check the operation of "DHPD_CL". Replace the drum phase sensor. Repair the drum drive section. Replace the PCU PWB.