Causes: Communication error between the CPU in the PCU PWB and the LSU PWB ASIC. Improper connection of the communication connector between the PCU PWB and the LSUcnt PWB. Harness trouble between the PCU PWB and the LSUcnt PWB. PCU PWB trouble. LSUcnt PWB trouble. LSU trouble.
Remedy: Check connection of the connector and the harness between the PCU PWB and the LSUcnt PWB. Check the LSUcnt PWB. Replace the PCU PWB. Replace the LSU.
Causes: Oscillation abnormality of the external oscillator used in the LSU ASIC. LSU ASIC abnormality on the LSU PWB. Frequency abnormality of picture transfer clock of SCN-MFP PWB
Remedy: Check or replace the LSUcnt PWB. Check connection of the connector and the harness between the SCN-MFP PWB and the LSUcnt PWB. Check or replace the SCN-MFP PWB.
Description: Image data trouble (Scanner expansion PWB (ACRE) ASIC)
Causes: An image data error occurs. An image data send error occurs. Scanner expansion PWB (ACRE) connection trouble. Scanner expansion PWB (ACRE) trouble. SCN-MFP PWB trouble.
Remedy: Check connection of the scanner expansion PWB (ACRE). Check the scanner expansion PWB (ACRE), and replace if necessary. Check the SCN-MFP PWB, and replace if necessary
Description: Image data decode error (Scanner expansion PWB (ACRE) ASIC)
Causes: A decode error occurs while high compression PDF images are made. (garbled data) Scanner expansion PWB (ACRE) connection trouble. Scanner expansion PWB (ACRE) trouble. SCN-MFP PWB trouble.
Remedy: Check connection of the scanner expansion PWB (ACRE). Check the scanner expansion PWB (ACRE), and replace if necessary. Check the SCN-MFP PWB, and replace if necessary.
Remedy: Check insertion of the scanner expansion PWB (ACRE) DIMM memory. Check the scanner expansion PWB (ACRE) DIMM memory, and replace if necessary. Check connection of the scanner expansion PWB (ACRE). Check the scanner expansion PWB (ACRE), and replace if necessary. Check the SCN-MFP PWB, and replace if necessary.