Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp MX6200N — Trang 21/26

Code: L4-35

Description: Fusing exhaust fan lock
Causes: When the fusing exhaust fan is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-36

Description: Fusing suction fan lock
Causes: When the fusing suction fan is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-38

Description: Machine ventilation fan center lock
Causes: When the machine ventilation fan center is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-39

Description: Machine ventilation fan right lock
Causes: When the machine ventilation fan right is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-40

Description: Ozone fan 1 lock
Causes: When the ozone fan 1 is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-41

Description: Ozone fan 2 lock
Causes: When the ozone fan 2 is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-42

Description: Ozone fan 3 lock
Causes: When the ozone fan 3 is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.

Code: L4-43

Description: Paper exit cooling fan center lock
Causes: When the paper exit cooling fan center is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.