Causes: When the fusing exhaust fan is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the fusing suction fan is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the machine ventilation fan center is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the machine ventilation fan right is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the ozone fan 1 is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the ozone fan 2 is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the ozone fan 3 is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Causes: When the paper exit cooling fan center is operated, the fan operation signal is not detected within the specified time.
Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.