Code: PC--

Description: Personal counter not detected
Causes: The personal counter is not installed. The personal counter is not detected. SCN Mother PWB trouble
Remedy: Check connection of the connectors and the harness. Replace the SCN Mother PWB.

Code: U1-01

Description: Battery trouble. RTC backup battery voltage fall
Causes: 1) Battery life 2) Battery circuit abnormality
Remedy: Check to confirm that the battery voltage is about 2.5V or above. Replace the battery.

Code: U2-00

Description: MFP EEPROM read/write error
Causes: MFPC PWB EEPROM trouble EEPROM socket contact trouble MFPC PWB trouble Strong external noises.
Remedy: Replace the MFPC PWB EEPROM. Replace the MFPC PWB. (Refer to the pages on the necessary works after replacing the MFPC PWB in the Service Manual, and perform the works.) Check the power environment.

Code: U2-05

Description: Erroneous detection of account management data
Causes: Breakage of the authentication DB is detected.
Remedy: When breakage of the authentication DB is detected, the MFP is rebooted and the DB tables are reconstructed, generating "U2-05". The message, however, is not displayed and only the trouble history is saved. The authentication data are cleared.

Code: U2-11

Description: MFPC PWB EEPROM counter check sum error
Causes: MFPC PWB EEPROM trouble EEPROM socket contact trouble MFPC PWB trouble Strong external noises.
Remedy: Use SIM16 to cancel the error. (The previous writing data (about the latest 8 sheets) are written into the EEPROM.) Replace the MFPC PWB. (Refer to the pages on the necessary works after replacing the MFPC PWB in the Service Manual, and perform the works.)

Code: U2-30

Description: MFPC PWB and PCU PWB manufacturing No. data inconsistency. Inconsistency between the manufacturing No. saved in the PCU PWB and that in the MFPC PWB.
Causes: When replacing the PCU PWB or the MFPC PWB, the EEPROM which was mounted on the PWB before replacement is not mounted on the new PWB. MFPC PWB trouble PCU PWB trouble
Remedy: Check that the EEPROM is properly set. Check to confirm that the EEPROM which was mounted on the PWB before replacement is mounted on the new PWB. Replace the MFPC PWB. (Refer to the pages on the necessary works after replacing the MFPC PWB in the Service Manual, and perform the works.) Replace the PCU PWB.

Code: U2-40

Description: SD card system storage data area error
Causes: A file error occurs in the SD card system storage data partition. SD card trouble MFPC PWB trouble
Remedy: Turn OFF/ON the power, and the backup data in the HDD are written into the SD card and the machine is automatically booted. Check the MFPC PWB, and replace if necessary. Check the SD card, and replace if necessary.

Code: U2-41

Description: HDD system storage data area error
Causes: A file error occurs in the HDD system saved data area, disabling backup of the saved file of the machine adjustment values in the SD card. HDD trouble MFPC PWB trouble
Remedy: Check the HDD, and replace if necessary. Check the MFPC PWB, and replace if necessary. When replacing the HDD and the MFPC PWB, refer to the chapter of "Necessary works and procedures of HDD and MFPC PWB replacement."