Description: Automatic toner density adjustment error (Overtoner)
Causes: Toner density sensor trouble. Charging voltage/ developing voltage trouble, toner density trouble, or developing unit trouble. MFPC PWB trouble.
Remedy: Replace the toner density sensor. Replace the developing unit. Replace the MFPC PWB.
Description: Automatic toner density adjustment error (Undertoner)
Causes: Toner density sensor trouble. Charging voltage/ developing voltage trouble, toner density trouble, or developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Replace the developing unit. Replace the MFPC PWB.
Causes: Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness. Developing unit trouble. MFPC PWB trouble
Remedy: Replace the toner density sensor. Harness and connector connection trouble. Replace the developing unit. Replace the MFPC PWB.
Causes: Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness. Developing unit trouble. MFPC PWB trouble
Remedy: Replace the toner density sensor. Harness and connector connection trouble. Replace the developing unit. Replace the MFPC PWB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.