Mã lỗi Sharp MXC310
Description: PCU PWB ROM error
Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. ROM trouble.
Remedy: Use SIM49-1 to perform the version-up procedure again. ROM trouble.
Description: SCU PWB ROM error
Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. ROM trouble.
Remedy: Use SIM49-1 to perform the version-up procedure again. ROM trouble.
Description: MFP PWB ROM error
Causes: Firmware combination error between the MFP and the image ROM (color correction ROM).
Remedy: Upgrade the firmware versions of the MFP and the image ROM (color correction ROM).
Description: Firmware version inconsistency (MFP - PCU)
Causes: Firmware combination error between the MFP and the PCU.
Remedy: Check the combination between the MFP and the PCU.
Description: Firmware version inconsistency (MFP - SCU)
Causes: Firmware combination error between the MFP and the SCU.
Remedy: Check the combination between the MFP and the SCU.
Description: MFP firmware version and EEPROM data version inconsistency
Causes: Inconsistency between the MFP firmware version and the EEPROM data version.
Remedy: Check the combination of the firmware.
Description: PCU firmware version and EEPROM data version inconsistency
Causes: Inconsistency between the PCU firmware version and the EEPROM data version.
Remedy: Check the combination of the firmware.
Description: SCU firmware version and EEPROM data version inconsistency
Causes: Inconsistency between the SCU firmware version and the EEPROM data version.
Remedy: Check the combination of the firmware.