Causes: An abnormality in the full wave signal frequency is detected. (The frequency is detected as 65Hz or above, or 45Hz or less.)PCU PWB trouble. Power unit trouble. Connection trouble of the connector and the harness. Power frequency, waveform abnormality.
Remedy: Replace the PCU PWB. Replace the power unit. Check connection of the connectors and the harness. Check the power waveform.
Code: L8-20
Description: MFP PWB - Mother board communication error
Remedy: Check connection between the mother board and the MFPC PWB. Check the earth line of the main unit. Replace the MFPC PWB. Replace the mother board.
Code: PC--
Description: Personal counter not detected
Causes: The personal counter is not installed. The personal counter is not detected.
Remedy: Check connection of the connectors and the harness. Replace the SCU PWB.
Code: U1-01
Description: Battery trouble
Causes: 1) Battery life 2) Battery circuit abnormality
Remedy: Check to confirm that the battery voltage is about 2.0V or above. Use SIM13 to cancel the trouble.