Mã lỗi Sharp MXM1204 — Trang 37/42

Code: U6-84

Description: Room humidity thermistor breakdown (1 series)
Humidity thermistor open or short
Causes: Humidity thermistor harness connection trouble Humidity thermistor trouble A3 2-stage LCT control PWB trouble
Remedy: Check connection of the harness and the connector of the humidity thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.

Code: U6-85

Description: Transport motor 1 trouble (2 series)
Transport motor abnormality
Causes: Motor lock Motor RPM abnormality Overcurrent to the motor A3 2-stage LCT control PWB trouble
Remedy: Use SIM04-03 to check the operation of the transport motor. Replace the motor. Replace the A3 2-stage LCT control PWB.

Code: U6-86

Description: 24V power trouble (2 series)
The DC24V power is not supplied to the A3 2-stage LCT.
Causes: Connection trouble or disconnection of the connector and the harness. A3 2-stage LCT control PWB trouble Power unit trouble
Remedy: Check the connector and the harness of the power line. Check the 24V voltage with the power unit and the A3 2-stage LCT control PWB.

Code: U6-87

Description: Power unit cooling fan motor trouble (2 series)
A3 2-stage LCT power unit section cooling fan motor abnormality
Causes: Motor lock, motor harness short/open, A3 2-stage LCT control PWB trouble, harness and connector connection trouble
Remedy: Check connection from the A3 2-stage LCT control PWB to the motor. Replace the A3 2-stage LCT control PWB. Replace the motor.

Code: U6-88

Description: EEPROM trouble (2 series)
The EEPROM contents are garbled.
Causes: A3 2-stage LCT control PWB trouble Malfunction caused by noises
Remedy: Replace the A3 2-stage LCT control PWB.

Code: U6-89

Description: Room temperature thermistor breakdown (2 series)
Room temperature thermistor open or short
Causes: Room temperature thermistor harness connection trouble Room temperature thermistor trouble A3 2-stage LCT control PWB trouble
Remedy: Check connection of the harness and the connector of the room temperature thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.

Code: U6-90

Description: Room humidity thermistor breakdown (2 series)
Humidity thermistor open or short
Causes: Humidity thermistor harness connection trouble Humidity thermistor trouble A3 2-stage LCT control PWB trouble
Remedy: Check connection of the harness and the connector of the humidity thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.

Code: U7-50

Description: MFPC PWB - Vendor machine communication error
Communication error between the MFP and the serial vendor.
Causes: Improper setting of the vendor machine specifications (SIM26-3). Vendor machine trouble. MFPC PWB trouble. Connector, harness connection trouble. Strong external noises.
Remedy: Cancel the error by turning OFF/ON the power. Check the connector and the harness in the communication line. Change the specifications of the vendor machine (SIM26-3). Replace the MFPC PWB.