Mã lỗi Sharp MXM1204 — Trang 7/42
Description: Controller connection trouble (scanner)
Controller connection trouble. Compatibility trouble between the controller and the scanner.
Causes: Combination error between the controller PWB and the engine.
Remedy: Check the controller PWB. Check combination between the controller PWB and the scanner.
Description: MFP EEPROM sum check error
EEPROM PWB information sum error
Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
Remedy: Replace the PWB.
Description: Scanner connection trouble
Unknown PWB identification information is detected on the SCU PWB
Causes: The PWB / firmware which is not supported by the machine specifications is connected. SCU PWB trouble. DSPF PWB trouble.
Remedy: Check the firmware kind and the version. Check the SCU PWB. Check the DSPF PWB.
Description: DSPF connection trouble
An unknown PWB identification information is detected in the DSPF PWB/ combination abnormality with the SCU PWB
Causes: PWB / firmware which does not support the machine specifications is connected.
Remedy: Firmware kind / Version check.
Description: DSPF connection trouble
An unknown PWB identification information is detected in the DSPF PWB/ combination abnormality with the SCU PWB
Causes: PWB / firmware which does not support the machine specifications is connected.
Remedy: Firmware kind / Version check.
Description: PWB information sum error (scanner detection)
EEPROM PWB information sum error
Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
Remedy: Replace the SCU PWB.
Description: PWB information sum error (DSPF detection)
FLASH ROM PWB information sum error
Causes: FLASH ROM device trouble. FLASH ROM device contact trouble. Device access error due to noises.
Remedy: Replace the DSPF PWB.
Description: MFP - SCU PWB communication error
Causes: SCU PWB - MFPC PWB connection trouble. SCU PWB trouble. MFPC PWB trouble.
Remedy: Check connection of the SCU PWB and the MFPC PWB. Check the ground. Replace the SCU PWB. Replace the MFPC PWB.