Causes: A3 2-stage LCT control PWB trouble Malfunction caused by noises
Remedy: Replace the A3 2-stage LCT control PWB.
Code: U6-89
Description: Room temperature thermistor breakdown (2 series)
Causes: Room temperature thermistor harness connection trouble Room temperature thermistor trouble A3 2-stage LCT control PWB trouble
Remedy: Check connection of the harness and the connector of the room temperature thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.
Remedy: Check connection of the harness and the connector of the humidity thermistor. Replace the temperature and humidity sensor. Check the A3 2-stage LCT control PWB.
Code: U7-50
Description: MFPC PWB - Vendor machine communication error
Remedy: Cancel the error by turning OFF/ON the power. Check the connector and the harness in the communication line. Change the specifications of the vendor machine (SIM26-3). Replace the MFPC PWB.
Code: U7-51
Description: Vendor machine error
Causes: Serial vendor machine trouble. Connector, harness connection trouble
Remedy: Err.XX is displayed on the operation panel of the vendor. (XX is the detail code.) Repair the vendor machine referring to the detail code. Check the connector and the harness in the communication line.
Code: U9-01
Description: Touch panel trouble
Causes: SUC PWB trouble
Remedy: Check connection signal between the SCU CPU and the touch panel controller.