Description: LDAP number over The number of LDAP exceeds the specification.
Causes:
Remedy: The number of destinations which are the targets of the global address search exceeds the max. number. Use a longer set of characters for search to narrow the area of search.
Description: Developing cartridge not installed The developing cartridge is not installed. Communication with the CRUM cannot be made in initial check of the CRUM.
Causes: Developing unit disconnection MCU PWB abnormality CRUM chip abnormality
Remedy: Check installation of the developing unit. Replace the MCU PWB.
Description: Duplex model memory error/ Image data error 1. The memory capacity for the duplex model machine is wrong. Insufficient memory capacity. 2. Duplex setting is set for a single surface model.
Causes: 1. The memory capacity on the MCU PWB is wrong. 2. Setting for a single surface model is wrong.
Remedy: 1. Use SIM26-39 to check to confirm that the memory capacity is 128MB. If it is not 128MB, replace the MCU PWB. 2. If SIM26-04 is set to 1, change the setting to 0. If it is 0, replace the MCU PWB.
Description: LSU trouble The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON)
Causes: LSU connector or LSU harness defect or disconnection Polygon motor rotation abnormality Laser beams are not generated. MCU PWB abnormality.
Remedy: Check connection of the LSU connector. Execute SIM 61-03 to check the LSU operations. Check that the polygon motor rotates normally. Replace the LSU unit. Replace the MCU PWB.