Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp MXM260N — Trang 10/11

Code: L8-10

Description: Power abnormality detection trouble
The power status monitoring signal keeps power OFF state after passing the specified time (2sec).
Causes: Circuit around the power status monitoring signal (PSSTS) failure.
Remedy: Check whether power status monitoring signal (PSSTS) on MCU PWB is OPEN or not. Replace MCU PWB.

Code: PF-00

Description: PF trouble
The copy inhibit command from RIC is received.
Causes: Judged by the host.
Remedy: Inform to the host.

Code: U1-01

Description: FAX battery error
The SRAM backup battery voltage on FAX control PWB falls.
Causes: The SRAM backup battery voltage on FAX control PWB falls.
Remedy: Check voltage of the SRAM back up battery. Replace the battery.

Code: U1-02

Description: PANEL LOW battery error
The voltage of the panel clock function battery falls.
Causes: The voltage of the panel clock function battery falls.
Remedy: Check voltage of panel clock function battery. Replace the battery.

Code: U2-04

Description: EEPROM communication error
EEPROM communication error
Causes: EEPROM defect. ICU PWB EEPROM access circuit failure.
Remedy: Check that the EEPROM is properly set. Clear trouble with SIM 16. Replace the MCU PWB.

Code: U2-20

Description: Machine speed code data error
The machine boot speed information is not identical to the model code speed information
Causes: EEPROM defect. SIM operation error.
Remedy: Check for matching of the machine and model information setting in SIM26-57.

Code: U7-00

Description: RIC communication trouble
Error in communication with RIC. Error in communication test after turning on the power or canceling SIM.
Causes: Connector harness contact trouble or disconnection. RIC control PWB trouble. MCU PWB failure. Malfunction by noises.
Remedy: Check the communication cable, connectors from the RIC box to the main body.

Code: U9-00

Description: Operation control PWB communication trouble
Communication trouble between MCU and the operation control PWB
Causes: Operation control PWB connector disconnection Harness failure of the operation control PWB and the MCU PWB
Remedy: Check the connectors and the harness of the operation control PWB and MCU PWB. Check the grounding of the copier. Check ROM on the operation control PWB.