Causes: Improper connection of the communication connector between the PCU PWB and the MFPC PWB. Harness trouble between the PCU PWB and the MFPC PWB PCU PWB or MFPC PWB trouble.
Remedy: Check connection of the connector and the harness between the PCU PWB and the MFPC PWB. Replace the MFPC PWB. Replace the PCU PWB.
Code: E7-49
Description: Water Mark data error
Causes: Watermark data trouble. HDD trouble. * When the wartermark data is not installed, U2-60 error occurs in booting.
Remedy: Use SIM62-02/SIM62-03 to check HDD read/write. If the result is NG, a remedy corresponding to E7-03 is required. Use SIM49-05 to update the watermark data. (Reinstallation)
Code: E7-50
Description: PCU connection trouble
Causes: A PWB/firmware which does not comply with the machine specifications is connected.
Remedy: Check the kind and the version of the firmware. LSU connection trouble. PCU PWB trouble. LSU trouble.